System information – Vaisala Hydromet Data Collection Platform User Manual

Page 135

Advertising
background image

Chapter 4 ___________________________________________________________ Troubleshooting

VAISALA______________________________________________________________________ 133

System Information

You can acquire a report that contains system information by using the
SYSINFO terminal command. The command lists parameters that are
useful especially when troubleshooting the system or when contacting
Vaisala HelpDesk.

Example:

/ > sysinfo
Serial # : E091041
Hardware : Rev B-003
Software : 7.00b
Checksum : 0ABACAB0
Boot sw version : 8.00
Program flash : 4096kB
System RAM : 2048kB
Free memory : 1297kB
Internal temp. : 25.50'C
Active errors : NO
Active warnings : NO
Piggyback - 0 : N/A
Piggyback - 1 : DSE101 rev: B serial no: 904460
Setup file : /Cfg/m120_425.adc
Setup for sw : 7.00
Setup creator : JI
Setup created : 2010-04-16T14:21:36+00:00
Setup CRC : EE848764
Lizard version : 7.00
System uptime : 168h 33min 51sec since Tue Apr 27
12:44:11 2010

where
Serial #

=

Serial number of the logger PCB

Hardware

=

Hardware revision of the logger PCB

Software

=

Software version for the operating software and
its checksum

Boot sw version =

Version of the QML logger boot software

Program flash

=

Total amount of program memory

System RAM

=

Total amount of memory on the logger

Free memory

=

Amount of free memory on the logger

Internal temp.

=

Internal temperature of the logger

Advertising