Table 39, Qml201c logger accuracy specifications – Vaisala Hydromet Data Collection Platform User Manual

Page 153

Advertising
background image

Chapter 5 ____________________________________________________________ Technical Data

VAISALA______________________________________________________________________ 151

Temperature (operating)

-50 ... +60 °C (-58 ... 140 °F);
extended -60 ... +70 °C (-76 ... 158 °F)

Temperature (storage)

-60 ... +70 °C (-76 ... 158 °F);
extended -60 ... +70 °C (-76 ... 158 °F)

Humidity

0 ... 100 %RH

Table 39

QML201C Logger Accuracy Specifications

Property

Description/Value

All data for ambient temperature range -50 ... +60 °C unless otherwise
specified
Temperature measurement
(Pt100 sensor, measurement
range
-50 ... +80 °C)
Typical uncertainty over
temperature range
-50 ... +60 °C

<

0.04 °C

Typical uncertainty over
temperature range
-60 ... +70 °C

<

0.08 °C

Maximum error over
temperature range
-40 ... +50 °C

Less than

0.10 °C

Maximum error at 0 °C

Less than

0.04 °C

Voltage measurement
uncertainty temperature
range: -50 ... +60 °C

5.0 V range

<0.06% of reading

100V

250 mV range

<0.04% of reading

50 V

250 mV range

<0.06% of reading

6 V

25 mV range

<0.06% of reading

5 V

Voltage measurement
uncertainty temperature
range: -60 ... +70 °C

5.0 V range

<0.10% of reading

150V

250 mV range

<0.08% of reading

80 V

250 mV range

<0.10% of reading

10 V

25 mV range

<0.10% of reading

10 V

Frequency measurements

0.003% + resolution up to 20 kHz

Common mode range

+7 V/-3 V

Table 38

QML201C Logger General Specifications
(Continued)

Property

Description/Value