Dual rs-485 module dsi486, version a, Figure 65, Dual rs-485 module wiring diagram – Vaisala Hydromet Data Collection Platform User Manual

Page 145: Table 33, Jumper settings for channel b in the rs-485 mode

Advertising
background image

Chapter 5 ____________________________________________________________ Technical Data

VAISALA______________________________________________________________________ 143

Dual RS-485 Module DSI486,
Version A

Channel A is always used in the RS-485 mode. In 2-wire RS-485, both
transmitted and received data is sent via this channel. In 4-wire RS-485,
this channel can either transmit or receive depending on the
configuration. Jumper X4 defines the line terminating resistor for the
data channel A. Remove the jumper X4 if you do not need the
terminating resistor of the dual RS-485 module.

Figure 65 on page 143

provides a schematic wiring diagram for dual RS-485.

1006-101

Figure 65

Dual RS-485 Module Wiring Diagram

Channel B can be used either in the RS-485 mode or in the RS-232
mode. In 2-wire RS-485, both transmitted and received data is sent via
this channel. In 4-wire RS-485, this channel can either transmit or
receive depending on the configuration.

Figure 65 on page 143

provides a schematic wiring diagram for the dual

RS-485 connection, the dual 2-wire connection utilizing both channels.
The correct jumper settings for the channel B are listed in

Table 33 on

page 143

. The jumpers are located on the module as illustrated in

Figure

66 on page 144

.

Table 33

Jumper Settings for Channel B in the RS-485 Mode

Jumper

Connected
Pins

Function

X3

1-2

Sets the RS-485 mode active for the channel
B.

3-4

X6

1-2

X5

1-2

The line terminating resistor is in use with RS-
485.