Chapter 4 ___________________________________________________________ Troubleshooting

VAISALA______________________________________________________________________ 137

Examples:

>\ disable RHMeasQMH101_1
>\ disable TAMeasQMH101_1
>\ disable WMS302_1
>\ enable PWD22_1

Upon successful completion of the commands, the response is as
follows:

Successfully disabled

or

Successfully enabled

Any other returned values indicate an error.

When the measurement input is disabled:

-

All other output values than status have undefined values.

-

Sensor status shows

disabled

; refer to the updated list of the

sensor statuses in

Table 13 on page 72

.

-

Value status shows

INVALID

and

NOT AVAILABLE

.

NOTE

For sensors that use more than one input channel, you need to enter
separate commands for each measurement. For example, you need to
control separately the TA and RH measurements of the air temperature
and relative humidity sensor.