Sensor status list, Table 13, Table 13 sensor status list – Vaisala Hydromet Data Collection Platform User Manual

Page 74

Advertising
background image

User's Guide ______________________________________________________________________

72 ___________________________________________________________________M210784EN-E

Sensor Status List

Table 13

Sensor Status List

Value

Description

Notes

0

Sensor is working properly (OK).

1

Not measured yet.

2

Interface is not initialized.

1

1. Value is available only for sensors with a serial interface.

3

Communication timeout has occurred.

1

4

Unknown data is received.

1

5

Communication is functioning, but the sensor reports
errors. Use sensor's own service interface to find out
the cause.

1

6

Sensor communication is paused because service
connection is opened.

1

7

Message sequence numbers are overlapping in the
Autotrac satellite transceiver interface.

1

8 ... 19

Not available.

20

Excitation failure is caused by overload in the
excitation output.

2

2. Value is available only for sensors with a conventional, that is, analog or

counter/frequency, interface.

21

The input voltage is out of range or the A/D conversion
has failed due to an internal error.

2

22

Sensor is disconnected or the connection cables are
broken.

2

23

Sensor output exceeds the min/max limits defined in
the Measurements view.

2

24

Change in sensor output has exceeded the maximum
step defined in the Measurements view.

2

25

An internal configuration error has occurred.

2

26

Error in reference measurement, which is usually
caused by damaged sensor/logger or electrical
interference.

2

27

Internal voltage error occurred or the logger is
damaged.

2

28

PMT16 calibration data error.

2

29

Data is invalid for unspecified reason.

2

30

The measurement or the sensor has been manually
disabled.

99

Sensor status is not supported.