The dual RS-485 module also provides an SDI-12 connection. The SDI-
12 line uses one wire for data and is limited to a maximum length of 60
meters.

Figure 68 on page 145

provides a schematic wiring diagram for

the SDI-12 connection and the 12 VDC power supply for a sensor. The
jumper settings should be as shown in

Figure 66 on page 144

.

Simultaneously with the SDI-12, you can connect channels A and B in
the 2-wire RS-485 mode. If you take all three channels in use, you either
need three free connectors in the flange or an optional junction box.

1006-103

Figure 68

Dual RS-485 Wiring Diagram for SDI-12 and
12 VDC Power Supply