The Gemini is a two input, microprocessor-based device which offers the features

and performance of a single (GEM 1000)/dual (GEM 2000) level preset counter or

sample time, rate indicator. The 6-digit display features 0.56" LEDs with negative

sign and overflow indicators. The internal precision is maintained to 9 digits. The 20

mA Current Loop Option (Gemini 2000 only) makes possible remote or

computerized monitoring or control of the count, Presets and Scale Factor.

Flexibility and usefulness are insured through user programmability. With

simple front panel keystrokes and rear panel switch settings, any one of a number

of configurations can be selected. Once the selection is made, all or part of the

keyboard can be disabled to protect the settings and guarantee that no unwanted

changes can occur during the measurements. All set-up data is stored in

E

2

PROM, which will hold data for a minimum of 10 years without power.

Whenever the power comes on, the Gemini performs a series of internal

diagnostics to verify the integrity of the stored data. There is also a self-test mode

and an ever-present “watchdog” timer to prevent processor lockup.

The construction of the Gemini features a metal, die cast bezel for maximum

durability with high quality appearance. The sealed front panel meets NEMA

4/IP65 specifications for washdown and/or dust. Electrical connections are made

with removable, plug-in terminal strips at the rear of the unit. Clamp type

pressure plate terminals accept stripped #14 AWG wire without lugs.

As a counter, the Gemini can monitor bi-directional, unidirectional (totalizer),

or quadrature signals. It can double or (with quadrature) even quadruple the

resolution of the incoming signal. Counting modes also provide for

anti-coincidence applications. Both channels of count information are monitored

simultaneously, no counts are lost, and the final output can be chosen as the sum

or difference of the two input channels.

As a rate indicator, a variety of sampling times are available. Accurate to one

hundredth of a percent, the sampling time can be set as 1, 2, 5, 10, 20, or 50 seconds.

The preset level(s) can be selected to control an open collector output(s). The

optional Gemini plug-in relay board makes it easy to field upgrade your Gemini

to provide 5 amp, 240 VAC relay output(s). The output(s) are also programmable

and can be set for terminate at the “other” output start, “other” output end, at

reset or reset end, after time delay, or boundary.

Preset and reset behavior of the output(s) and display are completely

programmable. The preset(s) can have a value ranging from -999999 to +999999.

Decimal placement will be the same as the decimal placement on the input value.

Various reset modes can be selected: manual reset to zero or preset; automatic

reset to zero or preset; or automatic reset after time delay. The manual reset will

always override automatic reset, if it has been enabled.

The scale factor, moveable decimal point, dummy right hand zeros, leading

zero blanking, and decade divider capabilities of the Gemini permit complete

control of the Gemini display. These features provide easy conversion of input

signals to desired measurement units (feet to meters, etc.). The input values can

be multiplied by any number from -5.9999 to +5.9999 with the scale factor. The

addition of up to 3 dummy right hand zeroes gives an effective display

multiplication of 10, 100, or 1000. Similarly, the decade divider provides 1, 2, or

3 decades of prescaling.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators not

equipped with safeguards. To do so, can be potentially harmful to persons or

equipment in the event of a fault to the unit.

PROGRAMMING THE GEMINI

When your Gemini arrives from the factory, it has already been programmed

to function as a preset counter.

The personality, functions, and modes are then set by pressing the appropriate

keys. A function is defined by a two-digit code which appears on the left side of

the display. The mode of that function is shown as a one-digit code on the right

side of the display. At times there will be a (-) sign modifier.