Red Lion GEMINI 2 User Manual

Page 18

Advertising
background image

PROGRAMMING INSTRUCTIONS FOR THE RATE INDICATOR VERSION OF THE GEMINI

The first part of this section provides detailed descriptions of the function

command codes for scale multiplier, leading zero blanking, output terminations,

etc. Then, using an actual application example, the programming instructions for

a rate indicator will be “walked through” to give the user a full understanding of

the Gemini programming procedure. The descriptions below give the Function

Command Code first, followed by the individual mode identifier. The Function

Command Code Summary in Appendix “D”, lists all codes. (Only commands

and modes pertaining to the rate indicator will be discussed in this section).

CODE 41 - UNIT PERSONALITY

Two basic personalities are available for the Gemini. They are the counter

mode and the rate indicator mode.
[41 2] RATE INDICATOR - Setting this mode selects the unit to function as a

rate indicator. This is the basic personality mode and must be programmed

before any other modes are set. (This command forces default mode values in

certain command codes.)

CODE 44 - NUMBER OF COUNT EDGES

The Gemini can be programmed for either single edge or two edge (doubling)

counting.
[44 1] SINGLE EDGE COUNTING - The unit counts on the negative going

(falling) edge of the count input signal.

[44 2] TWO EDGE COUNTING - This mode is used when doubling of the count

signal input is required. The unit counts on the positive going (rising) edge of

the count input signal, as well as, the negative going (falling) edge. This

effectively doubles the resolution of the input signal.

CODE 45 - SCALE MULTIPLIER

There are four scale multiplier values that are available. They are: 1; 0.1; 0.01;

and 0.001. They effectively divide the internal count value by 1, 10, 100, and

1000 respectively, to yield the displayed rate value.

[45 1] SCALE MULTIPLIER VALUE OF 1 - This value multiplies the internal

rate by 1.

[45 2] SCALE MULTIPLIER VALUE OF 0.1 - This value multiplies the

internal rate by 0.1. (Effectively divides by 10.)

[45 3] SCALE MULTIPLIER VALUE OF 0.01 - This value multiplies the

internal rate by 0.01. (Effectively divides by 100.)

[45 4] SCALE MULTIPLIER VALUE OF 0.001 - This value multiplies the

internal rate by 0.001. (Effectively divides by 1000.)

CODE 46 - DECIMAL POINT & LEADING ZERO BLANKING

There are six basic modes of decimal point placement on the Gemini. The

decimal point is placed to the right of the display digit that corresponds to the

mode identifier. (The right most decimal point, digit 1, is never turned on.) A “-”

sign in front of the mode identifier will inhibit leading zero blanking. The

absence of the “-” sign will enable leading zero blanking.
[46 1]

0

[46 2]

0.0

[46 3]

0.0 0

LEADING ZERO

[46 4]

0.0 0 0

BLANKING

[46 5]

0.0 0 0 0

[46 6]

0.0 0 0 0 0

[46 -1]

0 0 0 0 0 0

[46 -2]

0 0 0 0 0.0

[46 -3]

0 0 0 0.0 0

LEADING ZERO

[46 -4]

0 0 0.0 0 0

BLANKING INHIBITED

[46 -5]

0 0.0 0 0 0

[46 -6]

0.0 0 0 0 0

CODE 51 - RESET MODES (Manual Reset to Zero)

In the majority of rate indicator applications, the setting of function code 51 is

not relevant to the desired operation of the unit, and thus need not be

programmed. The Gemini is designed to automatically update at the end of every

sample time cycle, which will provide a continuous rate indication reading, as is

–16–