FACTORY SETTINGS

Keys Struck

Display

Description

4,1

41

1

Personality selected as Counter

4,3

43

1

Count with Inhibit

4,4

44

1

Count on one edge of input (no doubling)

4,5

45

1

Scale Multiplier of 1.0

4,6

46

1

Leading zero blanking and no decimal point

5,1

51

1

Manual reset-to-zero, as long as button remains PUSHED

5,2

52

3

Output 1 terminates at Reset, Normal Output Phase

5,3

0000.10

0.10 second Output 1 time delay. Note that this function

will display the actual amount of time delay, and not a

mode command. In this case, it displays a 0.10 indicating

0.10 seconds.

*5,4

54

3

Output 2 terminates at Reset, Normal Output Phase.

*5,5

0000.10

0.10 second Output 2 time delay. Note that this function

will display the actual amount of time delay, and not a

mode command. In this case, it displays a 0.10 indicating

0.10 seconds.

6,1

61

4

No right-hand dummy zeros

6,6

66

4

Reset enabled along with scale factor and presets.

3

01.0000

Scale Factor set to unity

1

000500

Preset 1 value equals 500

*2

001000

Preset 2 value equals 1000

When the unit is shipped from the factory, the functions and modes are

programmed as shown above.

*Applies to the Gemini 2000 only.