APPENDIX “B” - SPECIFICATIONS & DIMENSIONS

1. DISPLAY: 6-digit, 0.56" (14.2 mm) High LED display.

2. POWER REQUIREMENTS:

AC Power: Switch selectable 115/230 VAC (±10%), 50/60 Hz, 20 VA

DC Power: 11 to 14 VDC @ 0.7 amp maximum

3. SENSOR POWER: +12 VDC (±25%) @ 100 mA.

4. MEMORY: Non-volatile E

2

PROM memory retains all programming

information and count value when power is removed or interrupted.

5. INPUTS A AND B: Switch selectable to accept count pulses from a variety of

sources including switch contacts, outputs from CMOS or TTL Circuits, and

all standard RLC sensors.

Current Sourcing - Unit provides 3.9 KW pull-down load for sensor with

current sourcing outputs. (Max. input voltage = 28 VDC @ 7 mA.)

Current Sinking - Unit provides 7.8 KW pull-up load for sensors with current

sinking outputs. (Max. sensor current = 1.6 mA.)

Debounce - Damping capacitor provided for switch contact debounce. Limits

count rate to 100 Hz max. With 50% duty cycle.

Lo Bias - Input trigger levels V

IL

= 1.5 V, V

IH

= 3.75 V

Hi Bias - Input trigger levels V

IL

= 5.5 V, V

IH

= 7.5 V

Note: Bias levels given are ±10% @ 12 VDC. They vary proportionally with

sensor supply voltage.

6. MAGNETIC PICKUP INPUT:

Sensitivity - 150 mV peak nominal

Hysteresis - 100 mV nominal

Input impedance - 26.5 KW @ 60 Hz nominal

Maximum Input Voltage - ±50 Vp

7. MAXIMUM COUNT RATES:

Uni or Bi-Directional Modes - 9 KHz, 8 KHz (X2)

2-Input Anti-Coincidence Modes - 5 KHz, 4 KHz (X2)

Quadrature Modes - 5 KHz (X1), 4 KHz (X2 or X4)

Rate Indicator Version - 10 KHz, 8 KHz (X2)

8. CONTROL INPUTS:

Reset - Active low (V

IL

= 1.5 V max.), internally pulled up to +12 VDC (I

SNK

=

3 mA), Response time = 10 msec.

Program Disable - Active low (V

IL

= 1.5 V max.), internally pulled up to +5

VDC (I

SNK

= 1 mA).

Print Request - (GEM 2 only) Active low (V

IL

= 1.5 V max.), internally

pulled up to +5 VDC (I

SNK

= 1 mA).

9. SERIAL COMMUNICATIONS (Optional Gemini 2000 only):

Type - Bi-directional 20 mA current loop, 20 mA source provided. (Powers up

to 7 units in a loop with internal current source.)

Baud Rate - Programmable 300 to 2400.

Maximum Address - 16 units (0 to 15). (Actual number in a single loop is

limited by serial hardware specifications.)

Data Format - 10 bit frame, Odd parity (one start bit, 7 data bits, one odd parity

bit, and one stop bit.)

–40–

Note: Mounted units require a clearance of 6.8" (W) behind the panel.