Section 4. cables/wiring, 1 power and i/o cable connections, Cables/wiring – Campbell Scientific CC5MPX and CC5MPXWD Digital Network Cameras User Manual

Page 23: Power and i/o cable connections -1

Advertising
background image

4-1

Section 4. Cables/Wiring

4.1 Power and I/O Cable Connections

The wiring for the CC5MPXCBL1-L Power and I/O Cable is as shown in
TABLE 4-1 and FIGURE 4-1 through FIGURE 4-4.

It is essential that the Ground cable be connected first when
wiring the camera to the datalogger or the power supply.

TABLE 4-1. CC5MPXCBL1-L Power and I/O Cable Color Connections

Color Function

Connection

Black

Power Ground

System Ground

Red

Input Power

Power Source 9-30 VDC

Green

RS-232 TX (Output)

RS-232 Input (Pin 2 of a computer (DTE)
DB-9 connector or even-numbered
control port of a TX/RX pair on a CR800,
CR1000, or CR3000)

RS-485A when configured to RS-485

White

RS-232 RX (Input)

RS-232 Output (Pin 3 of a computer
(DTE) DB-9 connector or odd-numbered
control port of a TX/RX pair on a CR800,
CR1000, or CR3000)

RS-485B when configured to RS-485

Yellow Communication

Switched Power
(Output)

This line is intended to power a
communication device. The camera
switches the Input Power voltage to this
line.

Blue

Enable

Wakes up or initiates image/video
acquisition.

Clear Shield

Shield/Earth

Ground

Refer to Section 8 Internal Jumpers if the current RS-232 or RS-485 interface
option needs to be changed in the camera.

Refer to TABLE 4-2 to help determine which wires will need to be connected
for your camera application.

NOTE