Table 4-2 to – Campbell Scientific CC5MPX and CC5MPXWD Digital Network Cameras User Manual

Page 24

Advertising
background image

Section 4. Cables/Wiring

4-2

TABLE 4-2. CC5MPXCBL1-L Power and I/O Cable Wire Usage

Wire Color

Function

Connection Required

When not Used

Black Power

Ground

Always

Red Input

Power

Always

Green RS-232

TX

(Output)

or
RS-485 A

Green wire only needs to be
connected when RS-232 or RS-485
communications are used with
PakBus or the Device Configuration
Utility.

Connect to a gray
terminal block

White

RS-232 RX (Input)
or
RS-485 B

White wire only needs to be
connected when RS-232 or RS-485
communications are used for PakBus
or the Device configuration Utility.

Connect to a gray
terminal block

Yellow Communication

Switched

Power (Output)

Yellow wire only needs to be
connected if the camera will control
power that is supplied to a
communications modem.

For solar powered sites, the camera
can remove power from the modem
when communications are not
required.

Connect to a gray
terminal block

Blue

Enable

Blue wire is used when another
device will be triggering the camera
to capture an image or video.

Another device can also keep the
camera in the Fully On Power mode
by leaving the External Trigger Input
asserted.

Connect to a gray
terminal block

or


Connect to ground if
left in Factory Default
settings

Clear Shield

Always