7.2.1 Network Settings

The most common network settings are displayed first in the Network sub tab.
These settings are summarized in the following table.

TABLE 7-1. Network Settings

Configuration Setting

Description

Default Value

DHCP

Enables DHCP operation of the network interface. Operates
as a Static IP address if Disabled.

Disabled

Network IP Address

Only set if DHCP is Disabled

192.168.1.90 (Static)

Network Mask

Only set if DHCP is Disabled

255.255.255.0

Default Gateway

Only set if DHCP is Disabled

192.168.1.1

Primary Name Server

Only set if DHCP is Disabled

192.168.1.1

HTTP Port

Alternate ports can be used for the http interface. Options
are 80 or values between 1025 and 65535.

80

FIGURE 7-5. Network Settings

7.2.2 Ethernet Power Mode Settings

Clicking on the Power Mode sub tab will allow the user to edit the Ethernet
Power Mode setting. To reduce power consumption, the CC5MPX includes
the ability to control the power characteristics of the Ethernet port. Three
options are available (see FIGURE 7-6):

• Always On


This power mode offers the maximum availability of the Ethernet port. If
the camera is in the Fully On power state or the Partially On power state
then the Ethernet port will always be on and available for communications.

• Moderate


This power mode offers some power savings on the Ethernet port. This
mode is only recommended if the camera is being used in the Partially On
power mode. If the camera is in the Partially On power mode, then
incoming data packets will wake up the camera for communications.

Advertising