Figure 7-29. enable and capture time values -28 – Campbell Scientific CC5MPX and CC5MPXWD Digital Network Cameras User Manual

Page 64

Advertising
background image

Section 7. Camera Operation Using Web Browser Interface

7-28

The first step in setting up the Self Timed Capture is to select the Enable option
for the capture method (see FIGURE 7-29). Once Enable is selected,
parameters for the capture method can be edited.

FIGURE 7-29. Enable and Capture Time Values

The Self Timed Capture triggers are set up with the timing relative to midnight.
The first parameter to enter is the Start Minutes relative to midnight. The Start
Minutes parameter is the first occurrence of a capture event after Midnight. If
the first timed event is to begin right at midnight, then set this parameter to
zero. If the first timed event is at 7:00 a.m. then the Start Minutes would be
set to 420 as there are 60 minutes per hour and the start time is 7 hours past
midnight (7 hours * 60 minutes/hour = 420 minutes).

Similarly the Stop Minutes specifies when the capture events are to stop
relative to midnight. Set the Stop Minutes to 0 if there is no stop time. If a
stop time such as 7 p.m. (19:00 H) is desired then enter the value of 1140 as
there are 60 minutes per hour and the stop time of 7:00 p.m. is 19 hours past
midnight (19 hours * 60 minutes/hour = 1140 minutes).

Illustrations of the Start and Stop Times are shown in TABLE 7-6.