If the total travel
distance is...
Then...
Within the acceptable
values
Tighten the remaining casing bolts and torque to the specified value in a
crossing pattern.
Outside of the acceptable
values
One of the following is present:
• Worn parts
• Improper installation
• Too much pipe strain
Determine the cause and correct the set front clearance. See the Cold
temperature axial clearances for various service temperatures table in the
Commissioning, Startup, Operations, and Shut-down chapter.
7. Determine the gap, if any, between the frame foot and baseplate with feeler guages and shim
accordingly.
8. Install the frame foot hold-down bolts and tighten.
9. Lubricate the bearing frame with grease or oil.
10. Rotate the pump shaft by hand to make sure it rotates freely.
11. Reinstall the coupling hub and align the pump.
12. Reconnect the coupling.
13. Install the coupling guard and reconnect all auxiliary piping.
1
2
1.
Coupling guard
2.
Coupling
Attach the i-ALERT
™
Condition Monitor to the pump
CAUTION:
Always wear protective gloves. The pump and condition monitor can be hot.
Tools required:
• 5/32 inch hex wrench
1. Attach the condition monitor (761B) to the bearing frame (228A) using the hex-head screw (372T)
provided.
Maintenance
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual