Attach the i-alert™ condition monitor to the pump, Attach the i-alert, Condition monitor to the pump – Goulds Pumps 3180-86 - IOM User Manual

Page 105

Advertising
background image

If the total travel

distance is...

Then...

Within the acceptable

values

Tighten the remaining casing bolts and torque to the specified value in a

crossing pattern.

Outside of the acceptable

values

One of the following is present:
• Worn parts
• Improper installation
• Too much pipe strain
Determine the cause and correct the set front clearance. See the Cold

temperature axial clearances for various service temperatures table in the

Commissioning, Startup, Operations, and Shut-down chapter.

7. Determine the gap, if any, between the frame foot and baseplate with feeler guages and shim

accordingly.

8. Install the frame foot hold-down bolts and tighten.
9. Lubricate the bearing frame with grease or oil.
10. Rotate the pump shaft by hand to make sure it rotates freely.
11. Reinstall the coupling hub and align the pump.
12. Reconnect the coupling.
13. Install the coupling guard and reconnect all auxiliary piping.

1

2

1.

Coupling guard

2.

Coupling

Attach the i-ALERT

Condition Monitor to the pump

CAUTION:
Always wear protective gloves. The pump and condition monitor can be hot.

Tools required:

• 5/32 inch hex wrench

1. Attach the condition monitor (761B) to the bearing frame (228A) using the hex-head screw (372T)

provided.

Maintenance

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual