Goulds Pumps 3180-86 - IOM User Manual

Page 63

Advertising
background image

1. Run the unit under actual operating conditions for enough time to bring the pump, driver, and

associated system to operating temperature.

2. Shut down the pump and the driver.
3. Remove the coupling guard.

See Remove the coupling guard in the Maintenance chapter.

4. Check the alignment while the unit is still hot.

See Pump-to-driver alignment in the Installation chapter.

5. Reinstall the coupling guard.
6. Restart the pump and driver.

Commissioning, Startup, Operation, and Shutdown

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual

61