If your pump group

is...

Then...

XL1, XL2-S, and XL2 Evenly tighten the two jacking bolts (418) until the cover is free enough to

remove from the frame adapter. If required, gently tap the cover from the

frame adapter using a soft-blow hammer on the dry side of the cover.

This example shows the S, M, L, and XL:

This example shows the XL1, XL2-S, and XL2:

108

370H

418

184

351

5. Remove the four hex nuts (355) from the seal gland plate.
6. Loosen the set screws on the seal drive collar and slide the sleeve out of the seal.
7. Service according to the seal manufacturer’s instructions.

Maintenance

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual