Goulds Pumps 3180-86 - IOM User Manual
Page 81
Advertising

If your pump group
is...
Then...
XL1, XL2-S, and XL2 Evenly tighten the two jacking bolts (418) until the cover is free enough to
remove from the frame adapter. If required, gently tap the cover from the
frame adapter using a soft-blow hammer on the dry side of the cover.
This example shows the S, M, L, and XL:
This example shows the XL1, XL2-S, and XL2:
108
370H
418
184
351
5. Remove the four hex nuts (355) from the seal gland plate.
6. Loosen the set screws on the seal drive collar and slide the sleeve out of the seal.
7. Service according to the seal manufacturer’s instructions.
Maintenance
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
79