Check the shearpeller™ axial clearance, Impeller-clearance setting, Set the impeller clearance - dial indicator method – Goulds Pumps 3180-86 - IOM User Manual

Page 47: Check the shearpeller, Axial clearance

Advertising
background image

Cold temperature axial clearance for the open and closed impeller

For pumped liquid temperatures over 122°F (50°C), the cold setting must be increased to the values in this
table. This prevents the impeller from contacting the suction sideplate or wear ring due to shaft expansion
from the higher operating temperatures.

Temperature

Clearance

122°F (50°C)

0.015 in. (0.38 mm)

212°F (100°C)

0.018 in. (0.45 mm)

302°F (150°C)

0.020 in. (0.50 mm)

392°F (200°C)

0.022 in. (0.55 mm)

446°F (230°C)

0.026 in. (0.65 mm)

Check the Shearpeller

axial clearance

The Shearpeller

requires a large front clearance in order to handle stringy solids. The front clearance

between the Shearpeller

and the suction sideplate is 0.375 in. (9.50 mm). With this large clearance, the

pump is not as sensitive to small changes in the front clearance. No cold setting is required with the
Shearpeller

option due to the large clearances.

1. Back the Shearpeller

up until the back pump-out vanes contact the seal chamber.

2. Move the Shearpeller

forward 0.062 in. (1.57 mm).

The total axial adjustment of the Shearpeller

between the suction sideplate and the seal chamber is 0.437

in. (11.00 mm).

Impeller-clearance setting

Importance of a proper impeller clearance

A proper impeller clearance ensures that the pump runs at high performance.

WARNING:

• The impeller clearance setting procedure must be followed. Improperly setting the clearance or not

following any of the proper procedures can result in sparks, unexpected heat generation, and
equipment damage.

• If you use a cartridge mechanical seal, you must install the centering clips and loosen the set screws

before you set the impeller clearance. Failure to do so could result in sparks, heat generation, and
mechanical seal damage.

The clearance is set at 0.015 in. (0.4 mm) at the factory but could change due to piping attachment during
installation. A change in pump performance may be noted over time by a drop in head or flow or an
increase in power required.

Impeller clearance methods

You can set the impeller clearance with either of these methods:

• Dial indicator method
• Feeler gauge method

Set the impeller clearance - dial indicator method

WARNING:
Always disconnect and lock out power to the driver before you perform any installation or maintenance
tasks. Failure to disconnect and lock out driver power will result in serious physical injury.

1. Remove the coupling guard.
2. Set the indicator so that the button contacts either the shaft end or the face of the coupling.

Commissioning, Startup, Operation, and Shutdown

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual

45