Check the rotation, Impeller-clearance check, Impeller axial clearances – Goulds Pumps 3180-86 - IOM User Manual

Page 46: Check the rotation impeller-clearance check

Advertising
background image

b) Lift upwards.

1

2

1.

Coupling guard

2.

Coupling

Check the rotation

WARNING:

• Operating the pump in reverse rotation can result in the contact of metal parts, heat generation, and

breach of containment.

• Always disconnect and lock out power to the driver before you perform any installation or

maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.

1. Lock out power to the driver.
2. Make sure that the coupling hubs are fastened securely to the shafts.
3. Make sure that the coupling spacer is removed.

The pump ships with the coupling spacer removed.

4. Unlock power to the driver.
5. Make sure that everyone is clear, and then jog the driver long enough to determine that the direction

of rotation corresponds to the arrow on the bearing housing, or close-coupled frame.

6. Lock out power to the driver.

Impeller-clearance check

The impeller-clearance check ensures the following:

• The pump turns freely.
• The pump operates at optimal efficiency for long equipment life and low energy consumption.

Impeller axial clearances

Total axial adjustment

The total axial adjustment of the impeller between the suction sideplate or case ring and the stuffing box
cover should be between 0.028 in. and 0.087 in. (0.7 mm and 2.2 mm).

Commissioning, Startup, Operation, and Shutdown

44

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual