• Make sure the distance (H) from the bottom of the baseplate to the floor mounting pads is equal
to the dimension shown on the certified GA dimension drawing.
• Make sure the height of the centerline of the suction flange is equal to the dimension shown on
the certified GA dimension drawing
• In order to level the baseplate, the X1 and X2 dimensions can vary slightly from the dimensions
shown on the certified GA dimension drawing.
8. Fasten the lower and upper hex jam nuts against the hex nuts on each spring assembly.
NOTICE: Do not cut off the additional length of the studs. The additional length is needed in order
to remove the springs safely. Keep the additional threads lubricated with grease or a rust inhibitor.
Installation
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
29