Goulds Pumps 3180-86 - IOM User Manual

Page 50

Advertising
background image

5.

3/8 in. washer

6.

3/8-16 x 2 in. hex head bolt, 3 required

1. De-energize the motor, place the motor in a locked-out position, and place a caution tag at the starter

that indicates the disconnect.

2. Put the pump-side end plate in place.

If the pump-side end plate is already in place, make any necessary coupling adjustments and then
proceed to the next step.

3. Put the pump-half of the coupling guard in place:

a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.

1

2

3

4

1.

Annular groove

2.

Pump-side end plate

3.

Driver

4.

Pump half of the coupling guard

The annular groove in the coupling guard half must fit around the end plate.

1

2

3

1.

Annular groove

2.

End plate (pump end)

3.

Guard half

4. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Tighten securely.

Commissioning, Startup, Operation, and Shutdown

48

Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual

Advertising