Disassembly, Disassembly precautions, Tools required – Goulds Pumps 3180-86 - IOM User Manual
Page 70: Drain the pump, Ools required drain the pump
Disassembly
Disassembly precautions
WARNING:
• This manual clearly identify accepted methods for disassembling units. These methods must be
adhered to. Trapped liquid can rapidly expand and result in a violent explosion and injury. Never apply
heat to impellers, propellers, or their retaining devices to aid in their removal.
• Make sure that the pump is isolated from the system and that pressure is relieved before you
disassemble the pump, remove plugs, open vent or drain valves, or disconnect the piping.
• Always disconnect and lock out power to the driver before you perform any installation or
maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.
• Crush hazard. The unit and the components can be heavy. Use proper lifting methods and wear steel-
toed shoes at all times.
• The pump can handle hazardous and toxic fluids. Identify the contents of the pump and observe
proper decontamination procedures in order to eliminate the possible exposure to any hazardous or
toxic fluids. Wear the proper personal protective equipment. Potential hazards include, but are not
limited to, high temperature, flammable, acidic, caustic, explosive, and other risks. You must handle
and dispose of pumped fluid in compliance with the applicable environmental regulations.
NOTICE:
Make sure that all replacement parts are available before you disassemble the pump for overhaul.
Tools required
In order to disassemble the pump, you need these tools:
• Allen wrenches
• Cleaning agents and solvents
• Chisel
• Dial indicators
• Feeler gauges
• Hoist and strap
• Induction heater
• Pry bars
• Sockets
• Soft face hammer
• Spanner wrench
• Torque wrench
• Wrenches
Drain the pump
CAUTION:
• Allow all system and pump components to cool before you handle them to prevent physical injury.
1. Close the isolation valves on the suction and discharge sides of the pump.
You must drain the system if no valves are installed.
2. Open the drain valve.
Maintenance
68
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual