Product Familiarisation

Accessories

1 x Plumb Bob, 1 x Hex Key, 2 x Adjustment Tools

Unpacking Your Tool

• Carefully unpack and inspect your tool. Fully familiarise yourself with all

its features and functions

• Ensure that all parts of the tool are present and in good condition. If

any parts are missing or damaged, have such parts replaced before
attempting to use this tool

Operating Instructions

This is a precision instrument. Please read these instructions carefully and
follow guidance on correct handling and storage so that you get the best
out of your level and prolong its working life.

Transport

• Protect the instrument from excessive movement or knocks. Always

transport the instrument in the case provided

Prior to Use

• For optimum performance of your level, thoroughly check the instrument

before use

• Due to the precision nature of this instrument, even if it has been packed

correctly in its case it may need re-adjustment (See ‘Horizontality of the
line-of-sight’, below)

• Allow a short time before use for the instrument to adapt to the prevailing

temperature

Setting up

• Always handle the instrument with care when setting up
• Set the tripod (not included) at a comfortable height and so that the top of

the tripod is as level as possible. When working on soft ground, tread the
legs of the tripod firmly into the ground

• Attach the Level securely using the tripod fixing screw
• Centre the circular bubble in the vial by rotating the foot screws (Fig 6)

Fig.6

Pointing and focusing

• Point the Level towards a bright background or hold a white sheet of

paper in front of the lens

• Rotate the Eyepiece (4) until the cross hairs are sharp and black
• Turn the level towards the measuring staff (not included); you can use

the peep sight

• Looking through the eyepiece, rotate the Focus Dial (10) until the image

of the staff is sharp and clear

• Rotate the Horizontal Movement Dial (11) to set the vertical hair down the

centre of the staff

Measuring

Height measurement
• Read the staff where it is intersected by the middle hair. With metric

staffs it is usual to estimate to 1mm. The height reading in fig.7 is
3.456m

Fig.7

Distance measurement
• Read the staff where it is intersected by the upper and lower stadia hairs.

The difference multiplied by 100 is the distance from the instrument to
the staff

• For example, in fig.7 these readings are at 3.601m and 3.309m,

therefore, the distance from the instrument to the staff is: (3.601m -
3.309m) x 100 = 29.2m