2 current supply, Current supply – Festo Контроллер двигателя SEC-ST User Manual

Page 41

Advertising
background image

2. Fitting

2−5

Festo SEC−ST−48−6−P01−EN en 0606c

2.2

Current supply

Ģ

4700 ĢF / 100 V

Power unit

Fig. 2/2:

Warning

·

Use only PELV

circuits as per IEC/DIN EN 60204−1 (ProĆ

tective Extra−Low Voltage, PELV) for the electrical supply.
Consider also the general requirements for PELV circuits
in accordance with IEC/DIN EN 60204−1.

·

Use power

supplies which guarantee reliable electrical

isolation of the operating voltage as per IEC/DIN EN
60204−1.

By the use of PELV circuits, protection against electric shock
(protection against direct and indirect contact) is guaranteed
in accordance with IEC/EN 60204−1 (Electrical equipment for
machines, General requirements).

Caution
Serious damage to the device !

·

Make sure the polarity is correct.

·

Do

not disconnect any cables before the power supply

to the system is switched off.

For rated output in the designated application range a power
unit with 48 V DC is required. The SEC−ST can also be operĆ
ated with 24 V DC. Losses in the dynamics of the stepper moĆ
tors must be taken into account here (see data sheet for the
stepper motors).

Advertising