A.1.2 maximum ratings, A.1.2, Maximum ratings – Festo Контроллер двигателя SEC-ST User Manual
Page 66: A.1.2 maximum ratings inputs, Outputs
Advertising
![background image](/manuals/464487/66/background.png)
A. Technical appendix
A−4
Festo SEC−ST−48−6−P01−EN en 0606c
A.1.2
Maximum ratings
Inputs
Plugs
Pin
V
in
[V DC]
V
in
max.
[V DC]
I
in
I
in
max.
En +24
20...26 V
28 V
5.4...17.2 mA
22 mA
En +5
4...6 V
7.5 V
4.8...8 mA
8.4 mA
En −
0 V
−−−
−−−
−−−
Clk +24
20...26 V
28 V
5.4...17.2 mA
22 mA
X1
Clk +5
4...6 V
7.5 V
4.8...8 mA
8.4 mA
Clk −
0 V
−−−
−−−
−−−
Dir +24
20...26 V
28 V
5.4...17.2 mA
22 mA
Dir +5
4...6 V
7.5 V
4.8...8 mA
8.4 mA
Dir −
0 V
−−−
−−−
−−−
X3
+ 24...48
21...50 V
51 V
0...6.5 A
7 A
X3
GND
0 V
−−−
−−−
−−−
Outputs
Plugs
PIN
V
out
[V DC]
V
out
max.
[V DC]
I
out
I
out
max.
X1
Err+
4...26 V
30 V
5...20 mA
30 mA
X1
Err−
−−−
0 V
−−−
−−−
String A
24...48 V
51 V
0...6.5 A
7 A
X2
String A/
24...48 V
51 V
0...6.5 A
7 A
X2
String B
24...48 V
51 V
0...6.5 A
7 A
String B/
24...48 V
51 V
0...6.5 A
7 A
Advertising