1 commissioning the sec-st, Commissioning the sec−st, 1 commissioning the sec−st – Festo Контроллер двигателя SEC-ST User Manual

Page 57

Advertising
background image

4. Commissioning

4−3

Festo SEC−ST−48−6−P01−EN en 0606c

4.1

Commissioning the SEC−ST

·

Set the string current in accordance with chapter 1.7.2
Setting the current."

·

Make sure that the current set is adapted to the stepper
motor.

Caution
If the current is set too high, the motor may become overĆ
heated.

·

Set the desired step angle in accordance with chapter
1.7.1 The stepper mode."

·

Check that the step angle set is taken into consideration
by your position controller. (See also the manual for the
stepper motor indexer module for the SPC200).

When all connections have been made, the power supply can
be switched on. The connected motor may perform a step at
this stage. For this reason we recommend that the motor be
disconnected from the load in order that a test run can be
carried out.

Advertising