5 measures for complying with emc guidelines, Measures for complying with emc guidelines – Festo Контроллер двигателя SEC-ST User Manual

Page 54

Advertising
background image

3. Installation

3−12

Festo SEC−ST−48−6−P01−EN en 0606c

3.5

Measures for complying with EMC guidelines

Caution
Long lines reduce immunity to interference (EMC).

·

Do not exceed the maximum permitted cable lengths:
ć Control cable: 30 m
ć Power supply cable: 10 m
ć Motor cable: 10 m

If correctly fitted and if Festo cables are used for all the conĆ
nections, the controllers of the SEC−ST product family will
comply with the relevant regulations (see Declaration of ConĆ
formity).

Interference emission and resistance to interference of a
device always depend on the complete design of the drive,
which consists of the following components:

ć

the power supply

ć

the SEC−ST

ć

the motor

ć

the electromechanics

ć

the design and type of wiring

ć

the higher−order controller.