2 fault functions of the sec-st, Fault functions of the sec−st, 2 fault functions of the sec−st – Festo Контроллер двигателя SEC-ST User Manual
Page 62
5. Diagnosis and error treatment
5−4
Festo SEC−ST−48−6−P01−EN en 0606c
5.2
Fault functions of the SEC−ST
Fault
Cause
Possibilities
Power LED does not light up
No supply voltage
Ĉ Check supply cable
Ĉ Check power unit
Fault LED lights up red
Short circuit at motor output
Ĉ Check motor
Ĉ Check motor cable
Final stage overheated
Ĉ Winding resistor of motor too
small
Ĉ Motor defective, check
Ĉ Check fitting of controller
Motor does not move, power
LED lights up blue red fault LED
Dip switch 8 off
Ĉ Dip switch 8 on
LED lights up blue, red fault LED
is out
Motor cable defective
Ĉ Check motor cable
Brake not activated
Ĉ Open brake by applying
24ĂV DC
Motor loses steps
Frequency too high
Ĉ Check characteristic curve of
motor, check which torque
can be given
Motor cannot give torque
required
Ĉ Reduce frequency
(controller)
Fig. 5/1: