33

Operating conditions

Method of fastening

Front panel fitting or installation frame

Mounting position

As desired

Pneumatic characteristic values

Number of steps

Max. 12

Number of outputs

12

Number of inputs

12

Pneumatic connections

P (Operating pressure)

Plug nipple NW4

EInputs and outputs X and A

Plug nipple NW3

AUTO

Plug nipple NW3

L (Delete, setup)

Plug nipple NW3

MAN/P

Plug nipple NW3

Materials

Housing

ABS

Sub−base

PA12

Plug nipple

Brass