1-3

1.0 Before Use


1. 1 Installation Requirements

The following conditions are required for installation of the equipment.

1. Power source must be rated as follows.
120V plus or minus 10%, 16A and 50/60Hz
2. The equipment must be on a dedicated circuit.
3. The outlet must be near the equipment and easily accessible.


1. Make sure to connect this equipment to a grounded outlet.
2. For PLUGGABLE EQUIPMENT, the socket-outlet must be installed near the equipment

and must be easily accessible.



Site temperature range = 50 to 89 degrees Fahrenheit; 10 to 32 degrees Centigrade

Site humidity range = 20% to 80% RH. (NON CONDENSING)

Keep the printer away from water sources, boilers, humidifiers or refrigerators.


1. The installation site must not have open flames, dust or ammonia gases.
2. The equipment must not be exposed to air vents from air conditioners; it may affect the

image quality.

3. The equipment should not be exposed to the direct sunlight. Please draw curtains to

block any sunlight. When opening the Upper Unit to remove a mis-feed, do not expose
the Photoconductive Drum to strong (intense) light as this will damage the Drum.



Ozone will be generated while this equipment is in use, although the quantity generated
is within safe levels. (see certifications) Ventilate the room, if required.


Keep ample space around the equipment to ensure comfortable operation.
(Refer to the following figure.)
The equipment must be leveled and the floor strength must be ample to sustain the
weight of the equipment.



80cm

or

wider




45cm

120cm

or

wider

or

wider

Printer




80cm

or

wider