Transport and storage, Warranty and liability – IKA C 6000 isoperibol Package 2/12 User Manual

Page 8

Advertising
background image

8

Transport and storage

Transport and storage conditions

The system must be protected against mechanical

impact, vibrations, dust deposits and corrosive

ambient air during transportation and storage. It is

also important to ensure that the relative humidity

does not exceed 80%.
The appliance must be completely emptied before

storing and transportation.
In case of repair the device has to be cleaned and

free from any materials which may constitute a

health hazard.

For this use the „certifi cate of compliance“, down-
load the form from the IKA

®

website www.ika.

com.
If you require servicing, return the appliance in its

original packaging. Storage packaging is not suffi

cient. Please also use suitable transport packaging.

In accordance with IKA

®

warranty conditions, the

warranty period is 12 months. For claims under

the warranty please contact your local dealer. You

may also send the machine direct to our factory,

enclosing the delivery invoice and giving reasons

for the claim. You will be liable for freight costs.

The warranty does not cover worn out parts, nor

does it apply to faults resulting from improper use,

insuffi cient care or maintenance not carried out in

accordance with the instructions in this operating

manual.

Please read these operating instructions carefully.

IKA

®

only consider themselves to be responsible

for the safety, reliability and performance of the

appliance when
• the appliance has been operated in accordance

with the operating instructions,

• only persons authorised by the manufacturer

interfere with the appliance,

• only original parts and original accessories are

used for repairs.

The calorimeter system may be opened only by

an authorised Service Agent or Customer Service

Centre.
If service is required, we recommend that you

contact our customer service department
Furthermore, we refer you to the applicable safety

conditions and accident requirements.
IKA

®

is not responsible for damages or costs

resulting from accident, improper use of the

device or impermissible modifi cations, repairs or

renovations.

Warranty and liability

• Operating mode based on the adiabatic,

isoperibolic or dynamic principle at 22 °C, 25

°C or 30 °C (the beginning temperature of the

water in the inner vessel) depending on the

cooling water temperature.

Differences between the room temperature

and working temperature have an infl uence on

accuracy in dynamic mode; as a result, the working

temperature should always be kept similar to the

room temperature.

Cooling water

Mode of operation

Mode of operation

temperature

C 6000 global standards

C 6000 isoperibol

12 °C bis 20 °C Adiabatic 22 °C

-

Isoperibolic 22 °C

Isoperibolic 22 °C

Dynamic 22 °C

Dynamic 22 °C

20 °C bis 23 °C Adiabatic 25 °C

-

Isoperibolic 25 °C

Isoperibolic 25 °C

Dynamic 25 °C

Dynamic 25 °C

23 °C bis 27 °C Adiabatic 30 °C

-

Isoperibolic 30 °C

Isoperibolic 30 °C

Dynamic 30 °C

Dynamic 30 °C

User instructions