4 oil sampling, Procedure, Oil sampling -62 – JLG 1850SJ Service Manual User Manual

Page 232: Procedure -62, Oil sampling valve location -62

Advertising
background image

SECTION 5 - BASIC HYDRAULIC INFORMATION & HYDRAULIC SCHEMATICS

5-62

– JLG Lift –

3121619

5.4

OIL SAMPLING

See Figure 5-109., Oil Sampling Valve Location.

This machine is equipped with an oil sampling valve to
allow for verification of hydraulic oil condition.

Procedure

1.

Function the machine for approximately 15 minutes
operating all functions.

2.

Switch the select switch to the ground controls and start
the engine.

3.

Locate the oil sampling valve on the front of the main
control valve.

4.

Unscrew the knurled end which is attached to the chain.

5.

Place a drip pan under the spout and push in for approx-
imately 10 seconds. This should flush out the valve.

6.

Open and place the sample bottle under the spout.

7.

Push in on the end of the valve and fill up the bottle.

8.

Cap the bottle immediately.

9.

Thread the knurled cap back onto the valve.

10.

The sample is complete.

Figure 5-109. Oil Sampling Valve Location

Advertising