SECTION 6 - JLG CONTROL SYSTEM

3121619

– JLG Lift –

6-9

ENGINE SHUTDOWN:
7

0

1

DISABLED: No engine shutdown.

ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C or the oil
pressure is less than 8 PSI.

1

FUEL CUTOUT:
8

0

1

2

RESTART: Engine allowed to be restarted multiple times when very low fuel level is reached

ONE RESTART: Engine allowed to be restarted once for 2 minutes when very low fuel level is reached

ENGINE STOP: Engine not able to restart when very low fuel level is reached

0

TILT:
9

1

2

3

4

5

6

5 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more
than 5 degrees and above elevation; also reduces drive speed to creep.

4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees
and above elevation; also reduces drive speed to creep.

3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees
and above elevation; also reduces drive speed to creep.

4 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4
degrees and above elevation; also disallows tower lift up, tower telescope out, drive, main telescope out
and main lift up.

3 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 3
degrees and above elevation; also disallows tower lift up, tower telescope out, drive, main telescope out
and main lift up.

5 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 5
degrees and above elevation; also disallows tower lift up, tower telescope out, drive, main telescope out
and main lift up.

1

Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is also above elevation.

JIB:
10

0

1

2

NO: No Jib installed.

YES: Jib installed.

SIDESWING: Jib with Sideswing installed.

2

4WS:
11

0

1

NO: 2WS mode enabled.

YES: 4WS mode enabled.

1

Table 6-2. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number