SECTION 6 - JLG CONTROL SYSTEM

3121619

– JLG Lift –

6-17

JIB LEVEL:

ACCEL X.Xs

Displays/adjusts jib level acceleration

0.1 to 5.0 sec

1.5

DECEL X.Xs

Displays/adjusts jib level deceleration

0.1 to 3.0 sec

0.5

MIN UP XX%

Displays/adjusts minimum jib level up speed.
Same as Creep speed

0 to 65%

60

MAX UP XXX%

Displays/adjusts maximum jib level up speed

0 to 100%

100

MIN DOWN XX%

Displays/adjusts minimum jib level down
speed. Same as Creep speed

0 to 65%

60

MAX DOWN XXX%

Displays/adjusts maximum jib level down
speed

0 to 100%

100

GROUND
MODE:

M. LIFT UP XXX%

Displays/adjusts fixed main lift up speed

0 to 100%

60

M. lift DN XXX%

Displays/adjusts main lift down speed

0 to 100%

60

SWING XXX%

Displays/adjusts fixed swing speed

0 to 100%

60

PLATFORM LVL XXX%

Displays/adjusts fixed basket level speed

0 to 100%

75

PLATFORM ROT XXX%

Displays/adjusts fixed basket rotate speed

0 to 100%

75

MAIN TELE XXX%

Displays/adjusts fixed main telescope speed

0 to 100%

60

JIB (U/D) XXX%

Displays/adjusts jib lift speed

0 to 100%

80

Not displayed if JIB = 0

JIB (L/R) XXX%

Displays/adjusts jib swing speed

0 to 100%

80

Displayed if JIB = 2

JIB TELE XXX%

Displays/adjusts jib tele speed

0 to 100%

80

JIB LEVEL XXX%

Displays/adjusts jib level speed

0 to 100%

100

GEN SET/WELDER:

Engine XXXX RPM

Control generator/welder RPM. Not displayed if
GEN SET/WELDER = 0

1200-2800

1800

1800 for 60Hz ,1900 for 50Hz

1001172159-A

Table 6-4. Machine Personality Settings and Function Speeds

SUBMENU

(DISPLAYED ON

ANALYZER 1ST LINE)

PARAMETER

(DISPLAYED ON ANALYZER 2

ND

LINE)

DESCRIPTION

RANGE

DEFAULT

VALUES

TIME RANGE

(SEC)

Advertising