JLG 1850SJ Service Manual User Manual

Page 241

Advertising
background image

SECTION 5 - BASIC HYDRAULIC INFORMATION & HYDRAULIC SCHEMATICS

3121619

– JLG Lift –

5-71

4.

Install gauge at MS3, Activate swing left, the gauge

should read 2000 psi. (138 bar), The adjustment is

located at 9 o’clock beside port 3, Turn clockwise to

increase pressure, counter clockwise to decrease pres-

sure.

TELESCOPE OUT

NOTE:

NEVER increase telescope out pressure to achieve desired
telescope length.

1.

Install a high pressure gauge at the “M8” port of the
main valve bank.

2.

Plug the telescope out hose either at the valve bank
(port #8) or at the inlet of the telescope cylinder (V1).
Activate telescope out. The gauge should read 3000 psi
(207 Bar). The adjustment cartridge is located at 2
o’clock adjacent to M8 gauge port. Turn clockwise to
increase, counter clockwise to decrease.

Advertising