SECTION 5 - BASIC HYDRAULIC INFORMATION & HYDRAULIC SCHEMATICS

5-72

– JLG Lift –

3121619

TELESCOPE IN

1.

Install a high pressure gauge at the “M7” port of the
main valve block.

2.

Plug the telescope in hose either at the valve bank (port
#7) or at the inlet of the telescope cylinder (V2).

3.

Activate telescope in. The gauge should read 3300 psi.
(227 bar). The adjustment cartridge is located at 3
o’clock adjacent to “M7” gauge port. Turn clockwise to
increase, counterclockwise to decrease.