SECTION 7 - BASIC ELECTRICAL INFORMATION & ELECTRICAL SCHEMATICS

3121619

– JLG Lift –

7-7

7.4

AMP CONNECTOR

Assembly

Check to be sure the wedge lock is in the open, or as-shipped,
position (See Figure 7-7.). Proceed as follows:

1.

To insert a contact, push it straight into the appropriate
circuit cavity as far as it will go (See Figure 7-9.).

2.

Pull back on the contact wire with a force of 1 or 2 lbs. to
be sure the retention fingers are holding the contact
(See Figure 7-9.).

Figure 7-7. Connector Assembly Figure 1

Figure 7-8. AMP Connector

Advertising