Machine configuration programming information -8 – JLG 1850SJ Service Manual User Manual

Page 290

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-8

– JLG Lift –

3121619

Table 6-2. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number

NOTE:

The machine configuration must be completed before any personality settings can be changed. Changing the personal-
ity settings first and then changing the model number of the machine configuration will cause the personality settings
to return to default

The items marked in BOLD bold text on this sheet represent a new board that has never been configured.

MODEL NUMBER:
1

0

1

2

No Model

1500SJ

1850SJ

0

ENVELOPE HEIGHT:
2

0

1

1500SJ: 150' MAX

1850SJ: 185’ MAX

0

Note: The default settings (bold) will vary depending on the model selection with selection # 5 being the initial default setting.

MARKET:
3

0

1

2

3

4

5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0

ENGINE:
4

1

2

3

4

5

DEUTZ F4 TIER1: Deutz BF4M1011 Diesel (Tier 1)

DEUTZ F4 TIER2: Deutz BF4M2011 Diesel (Tier 2)

DEUTZ ECM: Engine Control Module

CAT Engine

DEUTZ ECM T4F: Engine Control Module (Tier 4 Final)

3

GLOW PLUG:
5

0

1

2

NO GLOW PLUGS: No glow plugs installed.

AIR INTAKE: Glow plugs installed in the air intake on the manifold.

IN-CYLINDER: Glow plugs installed in each cylinder.

2

STARTER LOCKOUT:
6

0

1

DISABLED: Automatic pre-glow time determined by ambient air temperature; engine start
can be attempted at any time during pre-glow.

ENABLED: Automatic pre-glow time determined by ambient air temperature; engine start is NOT permit-
ted until pre-glow is finished.

0

Advertising