6)

Close the battery with the lid “A” (Figure 1).

The charging voltage must never exceed 14.7 Volts and the charge intensity must always
be limited to 0.2% of the value indicated on the lid.

7.22.3 REPLACING THE BATTERY THERMIC VERSION

‑ Do not disconnect the cables with the engine running.
‑ Before disconnecting the cables, turn the engine key to position OFF.
‑ Disconnect the battery terminals, always starting from the negative pole (‑).
‑ Reconnect the cables, always starting from the positive pole (+).

When the battery cannot accumulate electric energy any longer, replace it with a new one
having the same characteristics.
See the specifications table on the battery.

7.22.4 BATTERY DISPOSAL

The batteries must be disposed of in compliance with the specific regulations in force.