JLG X19J Operator Manual User Manual

Page 67

Advertising
background image

6. USING THE MACHINE

6.1 SAFETY STANDARDS TO ADOPT BEFORE USING THE PLATFORM

6.1.1 RISK OF ELECTROCUTION

If the machine must be used near electric power lines, the user must remain at a suitable
distance from the latter. The table below supplies the values relating to the minimum distan‑
ce from electric power lines depending on the type of voltage.

SAFETY DISTANCE FROM POWER LINES

LINE RATED VOLTAGE

SAFETY DISTANCE

FROM

TO

(METRES)

0 V

300 V

5

300 V

50

K

V

5

50

K

V

200

K

V

5

200

K

V

350

K

V

6,1

350

K

V

500

K

V

7,6

500

K

V

750

K

V

10,7

750

K

V

1000

K

V

13,7

Keep a safe distance from mains power lines and electrical systems, considering the pos‑
sible range of movement of the platform and its oscillation, as well as the possible oscilla‑
tion of the power lines.

Before starting operation, examine the work area, taking note of overhead power lines,
moving machinery, such as overhead cranes and road, rail and building equipment.

6.1.2 DANGER DUE TO ATMOSPHERIC CONDITIONS

DO NOT WORK IN UNFAVOURABLE ATMOSPHERIC CONDITIONS

Do not work in the presence of storms, snow, fog or wind exceeding 12 m/s.
Do not operate the machine when the ambient temperature drops below–10°C or exceeds
+40°C. Do not recharge the machine when the temperature is below 0°C or above 40°C.

Should it unexpectedly rain, before resuming work always remember to check correct stabili‑
sation of the platform and make sure that the ground is solid. Make sure that water has not
penetrated into the electrical contacts.

X19JR0620113

BOOM LIFT MODELS X19J

JLG

63

Advertising