JLG X19J Operator Manual User Manual

Page 52

Advertising
background image

POSITION 6:
Position 6 displays the icon confirming that track movements (stabilisers, tracks, track exten‑
sion) are enabled.

This icon means that all conditions for operating the track movements have been checked.
No icon on means the stabilisers cannot be used and the track cannot be extended. The
machine, however, can travel even when the icon is off, as long as all 4 stabilisers are lifted
from the ground.

POSITION 7:
Position 7 is used for functional signals:

Emergency STOP pressed

Signals that one of the emergency stop buttons on the machine has not been released.

BATTERY VOLTAGE BELOW MINIMUM LIMIT.

Indicates that the battery charge level is below the minimum limit allowed. If this message
appears, it is advisable to recharge the battery, either by keeping the diesel or petrol engine
on, or by connecting to the network.

Signals an error in the battery management system of Lithium version.

In this position also other functional signals can be displayed that are useful for machine dia‑
gnostics.

X19JR0620113

48

BOOM LIFT MODELS X19J

JLG

Advertising