Make sure that all the emergency STOP buttons are released; this condition can be
checked on the remote control display, where no icon should appear in position 7.
If the operator attempts to start the machine with the emergency stop button still pres‑
sed, an error message will appear on the display when the start button is pressed.

If the operator attempts to start one of the two motors while the other is already run‑
ning, starting will be impossible and the icon showing the motor already on will appear
at the centre of the screen.

Use the button on the remote control to start the motor.

THE ENGINE MUST BE STARTED WITH ALL THE CONTROL BUTTONS AND JOY‑
STICKS IN NEUTRAL POSITION.
Always make sure that there are no foreign objects (for example, branches) that may acciden‑
tally operate a control, since the platform may move abruptly, independently of the opera‑
tor’s will, and cause serious injury or damage.
Make sure that all the manual controls for the proportional valves are at rest.

6.4.4 STOPPING THE ENGINE/MOTOR

To stop the engine, press again button 11 on the remote control; it allows the engine to be
switched off or on depending on its status.
To stop the electric motor, press button 12; it allows the electric motor to be switched off or
on depending on its status.

6.4.5 S

TOPPING THE MOTOR LITHIUM VERSION

To switch off the electric motor, release the button or the lever on the remote control or relea‑
se the emergency control key.

The motor will stop automatically in 3‑4 seconds.