BUTTON 5:

Used to select the travel speed and the engine/motor speed.
There are three speeds available:
• SLOW: engine at 1,500 rpm for the operation of the aerial part, at 2,200 rpm for the operation of

the carriage. Minimum possible speed for the tracks.

NORMAL: variable rpm according to the selected movement. Travel motors always with maxi‑
mum displacement, therefore medium travel speed

FAST: variable rpm according to the selected movement. Travel motors in automatic displacement
variation mode, therefore maximum travel speed.

The three speeds are selected by pressing button 5 in sequence, with a cyclical routine. The
selected speed is displayed on the screen in position 4.

BUTTON 6:

Enters the auto service menu (see paragraph 9 Remote control service menu).

BUTTON 7:

Used to automatically lower the stabilisers.