After the end of the procedure, always control that the spirit level is in the green zone. If this
does not occur contact JLG after sales service.

If during lowering one of the stabilisers does not touch the ground, the machine will conti‑
nue to operate the cylinder at the end of its stroke until the motor switches off or the self‑
levelling procedure ends. This situation is normal and indicates that the slope the machine is
situated on exceeds the allowable limit for stabilisation. If at the end of the stabilisation
phase the machine has to be lifted even further from the ground, a new self‑levelling proce‑
dure can be run.
NOTE: using the self‑levelling procedure does not affect the operation of the stabilisers in
manual mode.

• AUTOMATIC RAISING OF THE STABILISERS

Press and hold button 1 on the remote control.

The four stabilisers will start to lower the machine and then will retract completely.
The end of the automatic stabiliser raising cycle is shown on a screen for a few seconds. If
this screen is not shown, the automatic stabiliser raising procedure can still be considered
completed once all the four stabilisers have been completely retracted and consequently the
relevant cylinders are at the end of their stroke.

BOOM LIFT MODELS X19J