3.1 BATTERY CUTOUT SWITCH

This device, located on the left side of the electrical components compartment, is used to iso‑
late the machine’s electrical circuit, stopping any movements. It is well‑visible and easily
accessed without using tools. It only needs to be activated for prolonged machine downtime
or maintenance operations.
Turning the key clockwise closes the machine’s electrical circuit, while turning it anticlockwi‑
se isolates the machine’s electrical circuit and the key can be removed.

B

EFORE DISCONNECTING THE BATTERY BY MEANS OF THIS DEVICE

,

MAKE SURE THAT THE ENGINE

KEY IS IN POSITION

OFF

AND THE REMOTE CONTROL AND ELECTRONIC BOARD ARE OFF

.

3.2 DISTRIBUTOR PRESSURE RELIEF VALVES

All platform distributors have an over‑pressure valve that limits the pressure that can be rea‑
ched inside the calibration pressure plant of the valve itself.
These valves are calibrated in the platform inspection phase by qualified staff working and
must not be tampered with for any reason.