2N VoiceBlue MAX v1.5 User Manual

Page 84

Advertising
background image

84

2N TELEKOMUNIKACE a.s., www.2n.cz

®

System Settings

AT%S70=x.x.x.x – IP address
AT%S71=x.x.x.x – IP address mask
AT%S81= – Initialisation string for setting of mode connected to the gateway
COM2
AT%S90=x

Type of assignment of B-channels to GSM modules and X

0 – rotating
1 – locked
2 – according to credit

AT%S91=x,y

Way of call information recording

X:

0 – no record
1 – successfully connected outgoing call
2 – successfully connected incoming calls
3 – successfully connected incoming and outgoing calls
5 – all outgoing calls
6 – all incoming calls
7 – all incoming+outgoing calls

Y – to each call add NET info (1) or no (0)

AT%S93=x – Global selection of SIM card and X:

0 – according to GSM group
1-8 – number of SIM holder

AT%S98=xxxx – PIN code for SIM cards inserted in the gateway
AT%S99= dd.mm.yy.w/hh:mm:ss – Gateway date and time settings
AT%X00=hout,hin,min – Automatic logout of GSM modules

hout – hour when the modules start to log out randomly
hin – hour when the modules start to log in randomly
min – minimum number of modules in a group (2..15) that always remain
logged-in

AT%X80=name/pass

Username/password for access via IP port (this

parameter is write only – you cannot see its value)

System Control

AT&BSYS=RESET

Reset of PRIGW

AT&Gxx=RESET

Reset of GSM module xx

AT&Gxx=BLOCK

Block of GSM module xx

AT&Gxx=DOWN

Transfer of GSM module into the sleep mode

AT&Gxx=ON

Transfer of GSM module into the idle mode