Access modes – APG MND user manual User Manual
Page 7

Rev. A1, 5/14
MND
7
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
*Access Modes
The MND has several opera ng modes which will limit or lock access to the setup
menus. Refer to the mode descrip ons at the bo om of the page for more informa on.
To access the opera ng mode se ng, follow the steps below.
Step 1: Simultaneously press and hold the Decrease bu on and the Enter bu on for
approximately 5 seconds to bring up the *3 digit mode access number.
Step 2: Use the Increase/Decrease bu ons to change the value of he fl ashing digit,
and Enter bu on to accept the value and advance to the next digit. The mode
op ons are as follows:
Mode
Descrip on
000
Full Access. All menu op ons are accessible, including those that
may not be applicable to all MND confi gura ons.
001
Locks access to all setup menus. The Increase Bu on will scroll
through sensor readings when the MND is confi gured for mul ple
sensors. The Decrease/Power Bu on will turn on/off the display.
The Enter bu on will scroll between the maximum, minimum and
the current reading.
002
Hides the Output menu. All other setup menus are accessible.
003
Hides the analog op ons in the Output menu--only the relay op ons
are
accessible.
004
Hides the relay op ons in the Output menu--only the analog op ons
are
accessible.
005
All menus are hidden and all bu ons are lock, except the Decrease/
Power
bu on, which will power on/off the MND.
*Also see “
Se ng Mode Access Password”
under Sensor Label sec on of page 20.