2 command line interface introduction – Atop Technology EH7510 User manual User Manual

Page 101

Advertising
background image

Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0

95

3. The Serial Port Setup window pops up. Select appropriate port for Port, 115200

for Baud Rate, 8 bit for Data, none for Parity, and 1 bit for Stop.

Fig. 3.3

4. After finishing settings and clicking OK, a Command Line Interface (CLI) will be

brought up.

3.2 Command Line Interface Introduction

The Command Line Interface supports two types of privileges, which are operator and

manager privileges. Users with operator privileges may only view the information; while

those with manager privileges are allowed to view information and configure settings.

Operator and manager privileges are initially entered without the need of passwords, but a

user may assign password to both the operator and manager. If passwords are assigned,

then when a user attempts to enter the CLI next time, they will need to enter the correct

username and password.

If users enter the password for the operator, then the prompt changes to indicate operator

privilege. Users are now in the “user” mode:

Switch>

If users enter the password for the operator, then the prompt changes to indicate manger

privilege. Users are now in the “privileged” mode:

Switch#

If users are in the user mode and want to switch to the privileged mode, they may simply

type in the command “enable” and then enter the correct username and password following

the prompt:

Switch> enable

Username: (enter username here)

Advertising