7 modbus setting, 6 system time and sntp – Atop Technology EH7510 User manual User Manual

Page 26

Advertising
background image

Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0

20

2.3.6 System Time and SNTP

Fig. 2.14

This option, (Fig. 2.14) configures EH7510 time and date; it also supports Daylight Saving

Time and SNTP (See notes below for explanation).

Table 2.9

Label

Description

Factory Default

Current Date Allows local date configuration in yyyy/mm/dd format

None

Current
Time

Allows local time configuration in local 24-hour format.

None

System
Startup Time

Indicates how long the switch has been working.

Dependant

Daylight
Saving Time

Start Date: defines the start date of daylight saving.
End Date: defines the end date of daylight saving.
Offset: decide how many hours to be shifted
forward/backward when daylight saving time begins and
ends. See note below.

None

Enable
SNTP

Enables SNTP function. See note below.

Unchecked

NTP Server
1

Sets the first IP or Domain address of NTP Server.

time.nist.gov

NTP Server
2

Sets the second IP or Domain address of NTP Server.
Switch will locate the 2nd NTP Server if the 1st NTP
Server fails to connect.

Time-
A.timefreq.bldrdoc.gov

Time Zone

User’s current local time.

(GMT+08:00)Beijing,
Chongqing, Hong Kong

Time Server
Query
Period

This parameter determines how frequently the time is
updated from the NTP server.

259200 seconds.

Note:

- Daylight Saving Time: In certain regions (e.g. US), local time is adjusted during summer

season in order to provide an extra hour of daylight in the afternoon, and the time shifted

Advertising