Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0

25

Table 2.10

Label

Description

Factory Default

State

Enabled/Disable the PTP function

Unchecked

Version

Set the PTP operation version

1

Clock Mode

PTP (Precision Time Protocol) clock type selection.

End-to-End

Transport

Ethernet (layer 2) multicast transport or layer 3 (UDP/IP)
multicast transports for PTP (Precision Time Protocol)
messages’ selection.

Ethernet

Sync Interval

Set the interval of the sync packet transmitted time

1

Clock
Stratum

To set the Clock Stratum. The lower values take
precedence to be selected as the master clock in the
best master clock algorithm.

3

Clock Class

Clock’s accuracy level, it’s an attribute of an ordinary or
boundary clock; denotes time traceability or frequency
distributed by the grandmaster clock. Please refer to
IEEE 1588-2008, Table 5 for definitions, allowed values,
and interpretation.

248

priority 1

To set the clock priority 1 (PTP version 2). The lower
values take precedence to be selected as the master
clock in the best master clock algorithm.

128

priority 2

To set the clock priority 2 (PTP version 2). The lower
values take precedence to be selected as the master
clock in the best master clock algorithm.

128

UTC Offset

UTC offset value

0

Offset

To

Master

The offset time to the master clock

None

Grandmaster
UUID

The grand master UUID for PTP version 1

None

Parent UUID

The parent master UUID for PTP version 1

None

Clock
Identifier

The clock identifier for PTP version 1

None

The lower part of Fig. 2.20 shows how to configure PTP and to see its status per port.

Table 2.11

Label

Description

Factory Default

Port

Port number

None

Enabled

The port mode information, it indicates that the PTP port
function is enabled or disabled.

None

Status

PTP port operation status

None

Mode

Enabled/Disabled PTP port function

Disabled